Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Views
8907
Download
1299
from September 2014
 
©Journal of Sports Science and Medicine (2008) 07, 461 - 466

Research article
Validity of critical frequency test for measuring table tennis aerobic endurance through specific protocol
Alessandro M. Zagatto1,2, , Marcelo Papoti1, Claudio A. Gobatto1  
Author Information
1 Laboratory of Sport Applied Physiology, Sao Paulo State University-UNESP, Rio Claro, Brazil
2 Laboratory of Research in Exercise Physiology (LAPEFE), Federal University of Mato Grosso do Sul (UFMS), Campo Grande-MS, Brazil

Alessandro M. Zagatto
✉ Laboratory of Sport Applied Physiology, São Paulo State University, IB, Physical Education Department, Av 24A 1515, Bela Vista, Rio Claro SP, Brazil
Email: azagatto@yahoo.com.br
Publish Date
Received: 16-06-2008
Accepted: 18-08-2008
Published (online): 01-12-2008
 
ABSTRACT

The aim of this study was to validate critical frequency specific test (critf) for the estimation of the aerobic endurance in table tennis players. Methods: Eight male international-level table tennis players participated of this study. Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The critf was determined by applying three or four series of exercises to exhaustion (Tlim). The critf was evaluated by using lactate steady state test (90, 100, and 106 % of critf intensity). The other specific test was an incremental protocol used to determine the anaerobic threshold (AnTBI) and the onset of blood lactate accumulation (OBLA) using a ball thrower. Results: The critf (39.87 ± 3.31 balls·min-1) was not significantly different among AnTBI (48.11 ± 7.36 balls·min- 1) and OBLA3.5 (49.36 ± 12.04 balls·min-1) frequencies and it was correlated with AnTBI parameter (r = 0.78). At frequencies of the 90 and 100% of critf a dynamic equilibrium was verified in lactate concentration between the eighth and twentieth minutes. However, this dynamic equilibrium was not found at 106% intensity. Conclusion: The data indicate that in table tennis the critf model can be used for measuring the aerobic endurance.

Key words: Anaerobic threshold, Aerobic endurance, Blood lactate, table tennis


           Key Points
  • In table tennis is need the use of a specific protocol for evaluation of the aerobic endurance.
  • The critical frequency test in table tennis seems to represent the intensity of maximal equilibrium of lactatemia.
  • The critical frequency test can be used for measuring table tennis aerobic endurance through specific protocol.

INTRODUCTION

Racket sports are characterized by effort and rest periods. During these effort periods the movements of inferior limbs are rapid and powerful whereas, the movements of upper limbs are rapid only. Overall, the aerobic system is the predominant mechanism of resynthesis of energy (ATP) in these sports, but in effort periods the phosphagenic system (ATP-PCr) is the main mechanism to resynthesis of ATP (Zagatto et al., 2008). The measurement of the aerobic and anaerobic capacities and power are very important in sports to verify the physical aptitude status of athletes and to determine ideal exercise prescription. Despite the fact that the ATP-PCr is the main mechanism to resynthesize of ATP in effort periods in rackets sports, the aerobic system is responsible for the recovery between effort periods (rally) and is also the main tool for the prescription of exercises (i.e., anaerobic threshold). The aerobic endurance, called, anaerobic threshold (AnT) or maximal lactate steady state (MLSS) by some investigators, has been used as a main tool for the prescription of the intensity of the exercise, in both aerobic and anaerobic sports. However, despite the importance of verifying the aerobic endurance with precision, few studies have measured this aerobic component using specific protocols for racket-sports. Nevertheless, the majority of investigations that applied specific tests were performed in tennis, badminton and squash (Chin et al., 1995; Girard et al., 2005; 2006; Smekal et al., 2000; Wonisch et al., 2003). However, there have been few applications of specific procedures in table tennis (Morel and Zagatto, 2008; Zagatto and Gobatto, 2007; Zagatto et al., 2008).

The use of blood lactate concentration ([Lac]) has been the main physiological parameter used for determining aerobic endurance. However, the measurement of blood lactate currently requires invasive and expensive techniques to analyze the samples (Heck et al., 1985; MacIntosh et al., 2002). Monod and Scherrer, 1965 proposed the critical power model (critP) as a non-invasive procedure to estimate the aerobic endurance by measuring the time of exercise until exhaustion. The critical power model has been described as a good procedure for measuring the aerobic endurance (Dekerle et al., 2002; Toubekis et al., 2006; Wakayoshi et al., 1993). Several investigations have been adapted to the original critical power model for other sports and ergometers, such as swimming (Dekerle et al., 2002; Di Prampero et al., 2008; Toubekis et al., 2006; Wakayoshi et al., 1993), cycle ergometer (Bishop et al., 1998; Pringle and Jones, 2002), running (Bosquet et al., 2006), kayaking (Clingeleffer et al., 1994) and recentily table tennis (Morel and Zagatto, 2008; Zagatto and Gobatto, 2007; Zagatto et al., 2008). Although the critical power model has been adapted for table tennis and so-called critical frequency (critf), the validity of this procedure adapted for table tennis has not yet been verified. Therefore, the purpose of this investigation was to verify the validity of the critical power model adapted to table tennis (critical frequency test) to measure the aerobic endurance in a specific protocol using a mechanical ball thrower.

METHODS

Subjects

Eight male table tennis players of international level (mean ± SD - age 18 ± 3 years, body mass 67.0 ± 10.7 kg, height 1.76 ± 0.10 meters, body fat 14.7 ± 7.1 %, and body mass index 21.7 ± 2.9 kg.m-2) participated in this study. The players were fully informed of the nature and possible risks of the investigation before giving their written informed consent. The experimental procedure was approved by the Ethics Committee of São Paulo State University, Brazil. Experimental design Three sport-specific protocols were applied (critical frequency, lactate steady state test and incremental test) simulating forehand offensive strokes with ball shots from a mechanical ball thrower (NEWGY-PONG 2000, Newgy, CANADA). Prior to each sport-specific test a 4 minute warm-up exercise at moderate intensity (35 balls·min-1) was performed by subjects. The tests started five minutes after the end of the warm-up period.

Description and adaptation of the mechanical ball thrower

The NEWGY-PONG 2000 (Newgy, Canada) mechanical ball thrower has adjustments from 0 to 10 for speed control, lateral ball oscillation, and thrower frequency. Lateral ball oscillation was adjusted (setting 3) so that balls were shot systematically to different areas of the table tennis table (between the two extremities) so that the ball contacted the table between 50 and 60-cm away from the net (Figure 1). Ball speed was constant at to “setting 5”. Only ball frequency (exercise intensity) was changed for each effort (Zagatto et al., 2008).

To minimize interference from learning before the sport-specific test, the participants performed two familiarization sessions (done on consecutive days) at the same ball speed and lateral oscillation as applied in the test, and at varying ball shot frequencies. Each familiarization session lasted approximately 10 minutes.

Experimental procedures

Critical frequency test (critf): All the athletes performed three or four trials (separated by at least 2 hours and no more than 2 exercises per day) on a table tennis table. Exercise frequencies (intensities) corresponded to approximately 48, 56, 65, and 72 (balls.min-1) and were performed until technical or voluntary exhaustion (technical exhaustion occurred when four consecutive errors occurred in the offensive strokes developed with aid of coach). Exhaustion time (Tlim) was recorded. The critf was obtained by linear regression techniques between ball frequency (f) and the inverse of the Tlim (Tlim-1), corresponding to linear coefficient (y-intercept) (Figure 2).

Lactate steady state test: A sport- specific continuous test was applied after critf to verify the blood lactate behavior in intensities below critf (90% of critf), at critf (100% of critf) and upper critf (106% of critf). The test lasted 20 minutes at constant workload intensity. Capillary blood samples were taken from the ear lobe (25 µl) every four minutes of constant load to determine the blood lactate concentration during the test. The lactate steady state was defined as highest work rate that could be maintained without an increase of blood lactate by more than 1.0 mmol.L-1 between the 8th and the 20th min of constant load of the lactate steady state test (Gobatto et al., 2001).

Incremental test: The sport-specific incremental test consisted of an initial frequency of 34 balls min-1 and increments of 5 balls min-1 every 3 minutes until voluntary exhaustion. After each exercise stage blood samples (25 µl) were collect from the ear lobe to determine the lactatemia. Blood samples were also taken at 1, 3, 5 and 7 minutes after exercise.

Determination of anaerobic threshold (AnT) and Onset of blood lactate accumulation (OBLA) intensities: Anaerobic threshold (AnTBI) was determined by visual inspection of abrupt increase of the lactate concentration response using bi-segmented linear regression model (determined by three specialists in physiology of exercise) and the onset of blood lactate accumulation was corresponded to 3.5 mmol.L-1 fixed blood lactate concentration (OBLA3.5) (Figure 3).

Blood sample analysis: Blood samples (25 µL) were collected from a participant's ear lobe and transferred to 1.5 mL Eppendorf tubes containing 50 µL NaF (1% sodium fluoride). The homogenate was injected (25 µL) into an electrochemical lactate analyzer (Yellow Springs Instruments model 1500 Sport, Ohio, USA). The electrochemical lactate analyzer was calibrated after every five blood samples analysis using a standard-5.0 mmol.L-1 lactate solution. Blood lactate concentrations are expressed in millimoles per liter (mmol.L-1).

Statistical analysis

Data are expressed as mean ± SD. Significant differences for critf, AnTBI and OBLA3.5 were tested by one-way ANOVA. Newman-Keuls post hoc test was performed if statistical significance was obtained to identify which variables differed. Relationships between variables were examined by using a Product Moment Linear Correlation Analysis. The intensity of lactate steady state was determined by variation lower than 1.0 mmol·L-1 between the 8th and 20th minutes of constant exercise. The program STATISTIC for Windows 6.0 (Statsoft, Inc. 2001) was used for statistical analysis. In all cases, the statistical significance was set at p < 0.05.

RESULTS

The Tlim obtained in the exercise frequencies (48, 56, 65 and 72 balls.min-1) corresponded to 578.57 ± 203.95 s, 342.67 ± 109.70 s, 259.60 ± 38.90 s, and 188.83 ± 60.47 s, respectively. The critf was determined by linear regression between intensity of exercise and Tlim-1 and corresponded to 39.87 ± 3.31 balls min-1. The coefficient of determination (R2) of regression was 0.88 ± 0.11. A dynamic equilibrium of lactate was found at frequencies of 90% of critf (lactate mean value correspondents at 2.88 ± 1.19 mmol·L-1 and variation of lactatemia equivalent to 0.27 mmol.L-1) and 100% of critf (lactate mean value correspondents at 3.51 ± 0.34 mmol·L-1 and variation of lactatemia equivalent to 0.75 mmol.L-1). However, there was no lactate equilibrium at the frequency of 106 % of critf (lactate mean value correspondent at 3.80 ± 1.80 mmol·L-1 and variation of lactatemia equivalent at 1.46 mmol.L-1). The relationship between lactate concentration and exercise time verified by constant workloads at given frequencies of critf are showed in Figure 4.

The AnTBI was determined by three specialists in exercise physiology through a visual inspection following bi-segmented linear regression and were obtained, among them, a results variation of 2.86 ± 2.59% for [Lac] and 0.79 ± 0.36% for intensity (shot frequency). The AnTBI occurred at frequency of 48.11 ± 7.36 balls·min-1 and the [Lac] at AnTBI was 3.09 ± 1.65 mmol·L-1. The OBLA3.5 determined by fixed blood lactate concentration occurred at frequency of 49.36 ± 12.04 balls.min-1. The maximal frequency obtained in the incremental test was 58.81 ± 12.76 balls.min-1.

The critf, AnTBI and OBLA3.5 were not significantly different [F(1,6) = 3.03; p = 0.72]. However, despite the lack of significant differences between these variables, the AnTBI and the OBLA3.5 were 20.7% and 23.8% higher than critf, respectively. The critf was significantly correlated with the AnTBI (r = 0.78; p = 0.03) and also with the frequency at exhaustion (r = 0.79, p = 0.02), but not with OBLA3.5 (r = 0.42; p = 0.34). The AnTBI was also correlated with frequency at exhaustion (r = 0.94; p = 0.002).

DISCUSSION

The critical frequency test was shown to be a good method to aerobic endurance evaluation in a table tennis sport-specific test, and of lactate concentration was found to stabilize at 100% of critf intensity and significantly correlate with critf and AnTBI. The critical power model made some adaptations to the original model described by Monod and Scherrer, 1965, for application to swimming (Wakayoshi et al., 1993), cycle ergometer (Bishop et al., 1998; Jenkins and Quigley, 1990; 1992; Pringle and Jones, 2002), running (Bosquet et al., 2006; Smith and Jones, 2001), and kayaking (Clingeleffer et al., 1994), with valid and reliable results. The critical power model has been validated and correlated with the aerobic endurance determined by ventilatory threshold (Moritani et al., 1981), fatigue threshold (Devries et al., 1982), individual anaerobic threshold (McLellan and Cheung, 1992), onset of blood lactate accumulation (OBLA) (Papoti et al., 2005; Wakayoshi et al., 1993) and maximal oxygen uptake (Jenkins and Quigley, 1992), showing it to be a good tool for assessing the aerobic parameter. Wakayoshi et al. (1993) adapted the critP concept for swimming and called it critical swimming. Wakayoshi et al. (1993) found high correlation between critical swimming and anaerobic threshold and showed that in exercise 100% intensity of critical swimming a dynamic equilibrium occurred between the production and the disposal of blood lactate. However, this dynamic equilibrium did not occur when the intensity of exercise was increased by only 2%. Similar result was found by Jenkins and Quigley, 1990 on the cycle ergometer. In the present study we adapted the critical power model for table tennis using a mechanical ball thrower (robot) to control the exercise intensity (frequency). This adaptation for table tennis was initially reported by Zagatto and Gobatto (2002; 2007), but these researchers did not validate this test. The values of critf (39.87 ± 3.31 shots min-1) found here were similar to the ones previously obtained by Zagatto and Gobatto, 2002 (39.9 ± 1.3 shots min-1), but in this investigation higher values of AWC (99.46 ± 29.11 balls and 50.9 ± 6.9 balls, respectively) and linear coefficient (R2 = 0.88 ± 0.11, and R2 = 0.77 ± 0.06, respectively) were obtained. Table tennis requires a larger contribution of the ATP-CP system in effort periods (Faccini et al., 1989; Zagatto et al., 2008) and the difference found in AWC in these studies could be due a better ability of the athletes in this study.

Many investigations use approximately four trials in the critical power test, but other authors have used only two trials (Housh et al., 1990; Wakayoshi et al., 1993). Housh et al., 1990 investigated the number of workloads necessary to accurately determine the critical power. These authors found that critical power could be measured using only two trials. However, it should be noted that a possible mistake in Tlim in one or two of the workloads applied could have negative effects in the determination of the critical power and AWC results. In the present investigation, three or four trials were used for critical frequency determination. Nevertheless, the number of workloads used did not influence the results. The duration of the time trial could also influence the results of the critical power model (Bishop et al., 1998; Poole, 1986). Poole, 1986 reported that the ideal duration of trials that result in Tlim between 2 and 10 minutes. Workloads that generate a Tlim higher than 10 minutes can overestimate the AWC, and effort that generate short Tlim can overestimate the critP. The Tlim used in the present study respected the relation described by Poole, 1986 with Tlim variation between 3 and 9 minutes (188.33 ± 60.47 s to 578.57 ± 203.95 s).

The blood lactate concentration analyzed during the lactate steady state test showed a dynamic equilibrium in production and disappearance of blood lactate at frequencies of 90 and 100 % of critf. Nevertheless, with an increase of only 6% in the frequency (106% of critf), this dynamic equilibrium was not verified. Similar results were also found by Wakayoshi et al. (1993) in swimming and Jenkins and Quigley, 1990 on cycle ergometer. The frequency of 106% of critf applied in the lactate steady state test was chose, because of the difficulty in adjusting lower values of the equipment. The MLSS is usually applied in 30 minutes exercises, analyzing the lactate steady state in the last 20 minutes. But, the table tennis match and training consist in intermittent exercise, and the application of 30 minutes exercise would be very difficult for table tennis players perform. Moreover, even with the lactate steady state test lasting 20 minutes, it was very hard for the athletes to continuously perform the exercise for a long duration. Moritani et al. (1981) found a high correlation between anaerobic threshold, determined for ventilatory threshold, and critical power on the cycle ergometer (r = 0.92), also McLellan and Cheung, 1992 found a correlation between the critP and the individual anaerobic threshold (IAT) (r = 0.98) on the same ergometer. In the present investigation the critf also significantly correlated with the AnTBI (r = 0.78), but not with OBLA3.5. The OBLA3.5 was determined using a fixed [Lac] corresponding to 3.5 mmol.L-1, as proposed by Heck et al. (1985) who used this concentration when the exercise stage lasted three minutes. However, this protocol determined the anaerobic threshold for fixed [Lac] though mean values and not through individual values, and this could cause more variability in results. Heck el at. (1985) found a range of 2.40 to 4.35 mmol.L-1 for [Lac] for this duration of exercise. The lack of correlation between critf and OBLA3.5 can be explained by a possible mistake in the utilization of a fixed lactate concentration protocol. The mean lactate concentration in AnTBI was 3.09 ± 1.65 mmol·L-1 which is lower than 3.5 mmol·L-1 used in OBLA3.5. This difference in lactate shows that the use of a fixed lactate concentration protocol may result in a mistake in the results of aerobic endurance for table tennis. On the other hand, the use of other methods for anaerobic threshold determination could show better results than OBLA3.5, as the lactate threshold, individual anaerobic threshold or lactate minimum tests. Morel and Zagatto, 2008 investigated also the critf test for table tennis and found similar results, obtaining significant correlation between critf and the lactate minimum (r = 0.69), but not verified significant correlation between critf and OBLA3.5. (r = 0.06).

The table tennis is a sport that has few scientific studies and a lack of valid protocols to specifically measure aerobic endurance. Evaluation protocols showed physiological parameters and performance variables that respect the specificity of sports, because the use of non-specific protocols does not represent the same motor pattern performed in a match. The correlation found between critf and AnTBI (r = 0.78) and the dynamic equilibrium of blood lactate at 100% of critf frequency enables the utilization of the critf model for the evaluation of aerobic endurance in table tennis with a specific protocol by a non-invasive technique. The AnTBI and OBLA3.5 were 20.7 % and 23.8 % higher than critf, respectively, but not significantly different. Thus, these results should be taken into consideration. The low number of participants due to the difficulty in recruiting high level athletes may be a limitation of the study. The analyses of only forehand strokes may also be a limitation. Forehand, backhand and defensive strokes are performed in a mach may influence the physiological parameters of a match. However, in this study only the forehand strokes were analyzed. The analyses of the physiological characteristics of table tennis should be further investigated using other parameters, such as maximal oxygen uptake in specific situations.

CONCLUSION

The critical frequency intensity applied in a specific protocol showed a dynamic equilibrium of lactate in long duration exercise and significant correlation with AnTBI, but not with OBLA3.5. Therefore, the critf can be a valid procedure that may be used for evaluating the aerobic endurance of table tennis athletes by non-invasive techniques.

ACKNOWLEDGEMENTS

This study was supported by “Conselho Nacional de Desenvolvimento Científico e Tecnológico ”(CNPq - Procs. 130841/2003-0 and 301601/2006-2), “Fundação de Amparo à Pesquisa do Estado de São Paulo ”(FAPESP - Procs. 5778/1995 and 01/08295-2/2003) and Fundação de Apoio ao Desenvolvimento do Ensino, Ciência e Tecnologia do Estado de Mato Grosso do Sul (FUNDECT-Procs. 23/200.223/2007).

AUTHOR BIOGRAPHY

Journal of Sports Science and Medicine Alessandro M. Zagatto
Employment: Assistant Professor of the Exercise Physiology at the Department of Physical Education, Federal University of Mato Grosso do Sul (UFMS), Campo Grande-MS, Brazil.
Degree: MSc., PhD Student
Research interests: Exercise Physiology, monitoring training status and performance in team sports.
E-mail: azagatto@yahoo.com.br
 

Journal of Sports Science and Medicine Marcelo Papoti
Employment: Department of Physical Education, Laboratory of Physiology Applied to Sport (LAFAE), IB, Sao Paulo State University (UNESP), Rio Claro, Brazil.
Degree: MSc., PhD
Research interests: Exercise Physiology, monitoring training status and performance in team sports.
E-mail: mpapoti@yahoo.com.br
 

Journal of Sports Science and Medicine Claudio A. Gobatto
Employment: Department of Physical Education, Laboratory of Physiology Applied to Sport (LAFAE), IB, Sao Paulo State University (UNESP), Rio Claro, Brazil.
Degree: MSc., PhD
Research interests: Exercise Physiology, monitoring training status and performance in team sports.
E-mail: cgobatto@uol.com.br
 
 
REFERENCES
Journal of Sports Science and Medicine Bishop D., Jenkins D., Howard A. (1998) The critical power function is dependent on the duration of the predictive exercise tests chosen. International Journal of Sports Medicine 119, 125-129.
Journal of Sports Science and Medicine Bosquet L., Duchene A., Lecot F., Dupont G., Leger L. (2006) Vmax estimate from three-parameter critical velocity models: validity and impact on 800 m running performance prediction. European Journal of Applied Physiology 97, 34-42.
Journal of Sports Science and Medicine Chin M.I., Wong A.S.K., So R.C.H, Siu O.T., Steininger K., Lo D.T. (1995) Sport specific fitness testing of elite badminton players. British Journal of Sports Medicine 29, 153-157.
Journal of Sports Science and Medicine Clingeleffer A., McNaughton L.R., Davoren B. (1994) The use of critical power as a determinant for establishing the onset of blood lactate accumulation. European Journal of Applied Physiology and Occupational Physiology 68, 182-187.
Journal of Sports Science and Medicine Dekerle J., Sidney M., Hespel J., Pelayo P. (2002) Validity and reliability of critical speed, critical stroke rate, and anaerobic capacity in relation to front crawl swimming performances. International Journal of Sports Medicine 223, 93-98.
Journal of Sports Science and Medicine Devries H.A., Moritani T., Nagata A., Magnussen K. (1982) The relation between critical power and neuromuscular fatigue as estimated from electromyographic data. Ergonomics 25, 783-791.
Journal of Sports Science and Medicine Di Prampero P.E., Dekerle J., Capelli C., Zamparo P. (2008) The critical velocity in swimming. European Journal of Applied Physiology 1102, 165-171.
Journal of Sports Science and Medicine Faccini P., Faina M., Scarpillini E., Dal Monte A. (1989) Il costo energetico nel tennistavolo. Scuola Dello Sport 17, 38-42.
Journal of Sports Science and Medicine Girard O., Chevalier R., Leveque F., Micallefe J.P., Millet G.P. (2006) Specific incremental field test for aerobic fitness in tennis. British Journal of Sports Medicine 440, 791-796.
Journal of Sports Science and Medicine Girard O., Sciberras P., Habrard M., Hot P., Chevalier R., Mollet G.P. (2005) Specific incremental test in elite squash players. British Journal of Sports Medicine 339, 921-926.
Journal of Sports Science and Medicine Gobatto C.A., Mello M.A.R., Sibuya C.Y., Azevedo J.R.M., Santos L.A., Kokubun E. (2001) Maximal lactate steady state in rats submitted to swimming exercise. Comparative Biochemistry and Physiology, Part A 130, 21-27.
Journal of Sports Science and Medicine Heck H., Mader A., Hess G., Mücke S., Muller R., Hollmann W. (1985) Justification of the 4-mmol/l lactate threshold. International of Journal Sports Medicine 66, 117-130.
Journal of Sports Science and Medicine Housh D.J., Housh T.J., Bauge S.M. (1990) A methodological consideration for the determination of critical power and anaerobic work capacity. Research Quarterly of Exercise and Sport 661, 406-409.
Journal of Sports Science and Medicine Jenkins D.G., Quigley B.M. (1990) Blood lactate in trained cyclists during cycle ergometry at critical power. European Journal of Applied Physiology and Occupational Physiology 61, 278-283.
Journal of Sports Science and Medicine Jenkins D.G., Quigley B.M. (1992) Endurance training enhances critical power. Medicine and Science in Sports and Exercise 24, 1283-1289.
Journal of Sports Science and Medicine MacIntosh B.R., Esau S., Svedahl K. (2002) The lactate minimum test for cycling: estimation of the maximal lactate steady state. Canadian Journal of Applied Physiology 27, 232-249.
Journal of Sports Science and Medicine McLellan T.M., Cheung K.S. (1992) A comparative evaluation of the individual anaerobic threshold and the critical power. Medicine and Science in Sports and Exercise 24, 543-550.
Journal of Sports Science and Medicine Monod H., Scherrer J. (1965) The work capacity of a synergic muscular group. Ergonomics 8, 329-338.
Journal of Sports Science and Medicine Morel E.A., Zagatto A.M. (2008) Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis. Revista Brasileira de Medicina do Esporte 14, 518-522.
Journal of Sports Science and Medicine Moritani T., Nagata A., deVries H.A., Muro M (1981) Critical power as a measure of physical work capacity and anaerobic threshold. Ergonomics 24, 339-350.
Journal of Sports Science and Medicine Papoti M., Zagatto A., Mendes O.C., Gobatto C. (2005) Use of invasive and non-invasive protocol tests on aerobic and anaerobic performances prediction in Brazilian swimmers. Portuguese Journal of Sports Science 5, 7-14.
Journal of Sports Science and Medicine Poole D. (1986) Letter-to the editor-in-chief. Medicine and Science in Sports and Exercise 18, 703-705.
Journal of Sports Science and Medicine Pringle J.S., Jones A.M. (2002) Maximal lactate steady state, critical power and EMG during cycling. European Journal of Applied Physiology 88, 214-226.
Journal of Sports Science and Medicine Smekal G, Pokan R, Von Duvillard SP, Baron R., Tschan H., Bachl N. (2000) Comparison of laboratory and "on-court" endurance testing in tennis. International Journal of Sports Medicine 21, 242-249.
Journal of Sports Science and Medicine Smith C.G., Jones A.M. (2001) The relationship between critical velocity, maximal lactate steady-state velocity and lactate turnpoint velocity in runners. European Journal of Applied Physiology 885, 19-26.
Journal of Sports Science and Medicine Toubekis A.G., Tsami A.P., Tokmakidis S.P. (2006) Critical velocity and lactate threshold in young swimmers. International Journal of Sports Medicine 27, 117-123.
Journal of Sports Science and Medicine Wakayoshi K., Yoshida T., Udo M., Harada T., Moritani T., Mutoh Y., Miyashita M. (1993) Does critical swimming velocity represent exercise intensity at maximal lactate steady state?. European Journal of Applied Physiology and Occupational Physiology 666, 90-95.
Journal of Sports Science and Medicine Wonisch M., Hofmann P., Schwaberger G., Von Duvillard S.P., Klein W. (2003) Validation of a field test for the non-invasive determination of badminton specific aerobic performance. British Journal of Sports Medicine 337, 115-118.
Journal of Sports Science and Medicine Zagatto A.M., Gobatto C.A. (2002) Determination of an aerobic evaluation model on table tennis in a specific protocol using a robot. Table Tennis Player 15, 10-11.
Journal of Sports Science and Medicine Zagatto A.M., Gobatto C.A. (2007) Validação do modelo de freqüência crítica em protocolo específico através de método indireto, para o tênis de mesa. Lecturas Educación Física y Deportes 110, 1-7.
Journal of Sports Science and Medicine Zagatto A.M., Papoti M., Gobatto C.A. (2008) Anaerobic capacity may not be determined by critical power model in elite table tennis players. Journal of Sports Science and Medicine 77, 54-59.
 
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.